| Features |
1.Low price and high reliablity. 2.105 degrees output capacitor. 3.AC input power suitable for the world. 4.High efficiency and low operation temperature. 5.Soft-start current can reduce the AC input impact effecticly. 6.With short-circuit and overload protection. 7.100% full-load burn-in test. 8.Installed with EMI filter,minimum wave. |
|
| Model |
S-15-5 |
S-15-12 |
S-15-24 |
| DC output voltage |
5V |
12V |
24V |
| Output ovltage range(Note:2) |
+-2% |
+-1% |
+-1% |
| Rated output current |
3A |
1.3A |
0.7A |
| Output current range |
0-3A |
0-1.3A |
0-0.7A |
| Wave and noise(Note:3) |
50mVp-p |
50mVp-p |
100mVp-p |
| Intel stability(Note:4) |
+-0.5% |
+-0.5% |
+-0.5% |
| Load stability(Note:5) |
+-1% |
+-0.5% |
+-0.5% |
| DC Output power |
15W |
15.6W |
16.8W |
| Efficiency |
65% |
68% |
72% |
| Adjustable range for DC voltage |
+10%,-5% |
+-10% |
+-10% |
| AC input voltage range |
85-132VAC/170-264VAC selected by switch 47-63Hz,240-370VDC |
| Input current |
0.5A/115V 0.25A/230V |
| AC inrush current |
Cole-start current 15A/115V 30A/230V |
| Leakage current |
<0.5mA/240VAC |
| Over load protection |
105%-150%M Type:pulsing hiccup shutdown Reset:auto recovery |
| Over-voltage protection |
115%-135% |
| High-temperature protection |
............ |
| Temperature coefficient |
+-0.02% degrees(0-50 degrees) |
| Setup,rise,hold up time |
200ms,100ms,30ms |
| Vibration |
10-500Hz,2G 10min,/1cycle,period for 60min,each axes |
| Withstand voltage |
Input and output internal:1.5KvAC,Input and enclosure:1.5KvAC,Output and enclosure:0.5KvAC |
| Isolation resistance |
Input and output internal,Input and enclosure,Output and enclosure:500VDC/100MOhm |
| Working temperature and humidity |
-10 degrees-+60 degrees(Refer to output derating curve),20%-90%RH |
| Stoerall dimension |
-20 degrees-+85 degrees,10%-95%RH |
| Overall dimension |
99*97*35mm 120*46*32mm |
| Weight |
0.3kgs |
| Safety standards |
Meet UL 1012 requirement (Not apply for the mark) |
| EMC standards |
Meet FCC PART 15J Conduction class B |
| Note: |
1.The testing condition for the paramenter above is:230VAC input,rated load,25 degrees 70%RH,Temperature. 2.Error:Include the setting error,line stability and load stability.(Note:5) 3.Wave test:adoping A12 doubl wire for 20MHz,nd 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stavility test:The load is from 0% to 100%. |